Reactors

 

DAMPING REACTORS FOR CAPACITOR BANKS

The transient switching and inrush currents of a shunt capacitor bank can be limited by a damping reactor connected in series with the bank. Damping reactors are comparable to series reactors with low reactances. Their voltage strength requirements, however, are often higher than those of series reactors. Our damping reactors are used all over the world in various environmental conditions.

 

Reactors brochure (.pdf)

 

FILTER REACTORS

Filter has two functions, namely to produce capacitive reactive power at basic frequency and to filter out harmonics. A harmonic filter is designed to have a small impedance between phase and earth, or between the phases at required harmonic frequency. Therefore the harmonic current will flow into the filter and not into the network. Normally each harmonic frequency required has a separate filter circuit. For higher harmonic frequencies, a wide-band filter is used. Nokian Capacitors Ltd. manufactures filter reactors to the customer's specification. Our filter reactors may be equipped with off-load tappings to make an adjustment possible at the required frequency.

 

Reactors brochure (.pdf)

 

SHUNT REACTORS

Shunt reactors are used to compensate for capacitive reactive power generated by long lightly loaded transmission lines. Shunt reactors are switched on/off by breakers and are normally connected to the tertiary winding of the main transformer. Reactors are available up to 36kV voltage level and 100MVA power.

 

Reactors brochure (.pdf)

 

CURRENT LIMITING REACTORS

Current limiting reactors are mainly used to limit short-circuit current, i.e. to prevent fault currents from rising to values dangerous for the equipment. Normal types of breakers, cables and equipment can thus be used instead of those with higher short-circuit power rating. This means savings in money. A series reactor consists of three phase coils, generally stacked on each other with support insulators between them. The support insulators provide enough space between the phases to ensure that the mutual inductance between the coils is negligible compared to the main inductance. In making the concrete foundations, close loops in the reinforcement steel must be avoided. The magnetic clearances for metal constructions are given in our reactor specification.

 

Reactors brochure (.pdf)

 

THYRISTOR CONTROLLED REACTORS

Thyristor controlled reactors, called TCR-reactors, are used in Static Var Compensation systems. TCR-reactors are similar to shunt reactors, but the current is continuously controlled by thyristor valves. The three phase reactor is delta connected. Each phase reactor is split into two coils and the thyristors are connected between the coils. TCR reactors are available up to 36kV voltage and up to 180MVA power.

 

Reactors brochure (.pdf)

 

NEUTRAL EARTHING REACTORS

A neutral-earthing reactor is connected between the neutral point of the three-phase system and the earth. Its purpose is to limit the line-to-earth current of a directly earthed network or to reduce the line-to-earth current of an insulated line to a value suitable for protection.

 

Reactors brochure (.pdf)

 